Latest Drdish shows dramatic increase of about +2dB C/N when he freeze a LNB down to -34 degrees celsius with a freeze spray. This is a temporarily procedure of course. Is there any good permanent freezing solution for resonable money that could cool down a LNB to -40 or around that? Drdish talked about peltier elements that could be placed on both sides of LNB. | ||
| | |
| | #2 | |||
| Amo Amas Amant Admin Join Date: 18-11-2004 Location: NW England (Siberia)
Posts: 8163
Thanks: 18
Thanked 256 Times in 239 Posts
My System: IDD CI24 ECONO MM Penta 1.20 Galaxy II 1.2Mtr Polar MTG yes it has been on the arc for 21 years and is still driven by a modified wiper motor from a Ford Anglia. It's like me sometimes groans but always performs ![]() Saved us from the black plague of ignoratio elenchi, he awaits a special badge with jugs |
For someone with time and money on their hands it may indeed work but smacks of desperation to me but if you wanted them they are easy enough to get hold of here.
__________________ War does not determine who is right, it determines who is left! Formerly toppervte33h whose six pack has turned into a keg Help support this web site by making a donation Or use other options to help support Sats UK Show Your Support by clicking the button ![]() Thank you. Freddie Flintoff is back | |||
| | |
| | #3 | ||
| Regular Member Join Date: 25-04-2005 Location: Austria
Posts: 974
Thanks: 1
Thanked 94 Times in 89 Posts
My System: 1,25 Fibostop Jäger Smr 1224 Dual Axsis Echostar Dvr 7000 Monterey 140 Tagra 2,20 M Fullsize Dish Echostar 2,40m Mesch for cband! | maybe we must move to antarctica,then it is cold enough ![]() i think a profesional solution coasts many 1000€++ most lnb i think will fault after a short period of time,try to put your lnb in a freezer 2 hours,then install it rapedly and check the signal! | ||
| | |
| | #4 | |||
| Regular Member Join Date: 26-07-2005 Location: London
Posts: 126
Thanks: 274
Thanked 7 Times in 7 Posts
My System: dvb-s pci card 85 cm offset dish | How does an increase of 2dB C/N convert into dish size requirements decrease? Would that make 1,20m dish act like a 1,80m one or better. Could zone 1 sky minidish be used in zone 2 dish zone ? Thanks in advance | |||
| | |
| | #5 | |||
| Site administrator Join Date: 26-07-2003 Location: Scottish Borders
Posts: 14913
Thanks: 7
Thanked 581 Times in 466 Posts
My System: Sky UK. FTA analogue & digital satellite from 5 fixed dishes (5E/7E/9E/13E/16E /19E/23E/28E) Pace MSS100, Echostar IP3000VA, Technomate TM-1000D, Dreambox 7020S ![]() The last noble sat warrior to fly the olden flag of Analogue | Theres no substitution for more metal collecting signal - theres never going to be a practical solution for dramatic cooling of lnb in a hobby situation. Water based peltiers can cool things a bit but unless you go for industrial cooling fluids you arent going to get below zero celcius. Freezy spray might make some dramatic temporary improvements but how are you going to keep the temp at that -30 temp for hours on end without some pretty heavy duty cooling kit??
__________________ | |||
| | |
| | #6 | |||
| Mod and septic resident Join Date: 01-01-2000 Location: London SW
Posts: 7393
Thanks: 1
Thanked 43 Times in 41 Posts
|
We were able to get a stable temperature of -32 C within the LNB casing from a standard freon jacket provided by a small tabletop freezer, giving the impression of a 40% gain in dish area (20% gain in dish size) similar to upgrading from a 1.2 to a 1.5m reflector. If you want a refined product though and are prepared to modify it for use with your satellite gear, then the following link from Denmark is probably the best one to go for. _http://www.asetek.com/content/view/51/101/ Reports claim that the cooling can reach -40 C in the area surrounding the microprocessor in a PC cabinet, down from an ambient 15 C on a forced air system, which is quite impressive The LNB doesn't produce heat like a microprocessor does, however additional shielding should be used deflect heat generated by the dish reflector in warmer climates. It is also adviseable to coat the finished LNB PCB in silicone, to prevent the condensation mucking up your hard work.
__________________ There is a very fine line between "hobby" and "mental illness" | |||
| | |
| | #7 | |||
| Regular Member Join Date: 26-07-2005 Location: London
Posts: 126
Thanks: 274
Thanked 7 Times in 7 Posts
My System: dvb-s pci card 85 cm offset dish |
Hello, At what minus temperature point could the impression of DOUBLING the dish size possibly occur??? Would you say that at -100*C, it would be like doubling the dish size? Could it also be that at -150*C, it's like 3x dish size, at -200*C it's 4x dish size and near absolute zero it'd be 8x dish size??? Who knows (or guesses)? Thanks in advance. | |||
| | |
| | #8 | ||
| Mod and septic resident Join Date: 01-01-2000 Location: London SW
Posts: 7393
Thanks: 1
Thanked 43 Times in 41 Posts
| The noise figure of the LNB is only one factor in the total loss of a system, and so there is no direct correlation between dish size and a drop in noise temperature Noise temperature of an LNB forms only part of the total signal path, and the eventual quality of signal (G/T ) of the system is governed by everything else making up the link. It does not replace or form part of any of the other parameters in the equation.
__________________ There is a very fine line between "hobby" and "mental illness" | ||
| | |
| The Following User Says Thank You to Channel Hopper For This Useful Post: | divibi (09-08-2008) |
| | #10 | ||
| Member Join Date: 03-02-2007 Location: West Yorkshire
Posts: 18
Thanks: 0
Thanked 2 Times in 2 Posts
My System: 1.2M Channel Master, C120 Invacom 0.3 LNB & Feedhorn, with Humax HDCI2000. 68.5E - 61W | Interesting topic! Is this definately safe to do? Freezing the LNB won't damage it? Also, i presume this means we should get better signals in cold weather than in warm weather? | ||
| | |
| | #11 | |||
| Mod and septic resident Join Date: 01-01-2000 Location: London SW
Posts: 7393
Thanks: 1
Thanked 43 Times in 41 Posts
| Better signals are achieved in colder weather, but this is not solely down to the LNB temperature. The dish material, feed, air temperature, and even the ground temperature all contribute to the overall noise received at the tuner. Additionally noise figures are measured in Kelvin, and so the starting point for the calculations is at -273 degrees Celsius, a drop of 50 degrees isn't so much in the great scale of things (but will make a difference).
__________________ There is a very fine line between "hobby" and "mental illness" | |||
| | |
| | #12 | |||
| Design Engineer/Installer Join Date: 08-08-2007 Location: Central UK near Jodrell
Posts: 382
Thanks: 24
Thanked 44 Times in 43 Posts
My System: 75e-75w C & KU, 36v diseqc Anlg to HD Channel Master C120 dishes, stbs, lnbs, motors, too much to list | silicone to seal it from condensation...... I liked that, or using another sealant material. Venting would increase condensation and freezing on the LNB ... if it was working at minus 30C then all moisture in passing air would want to condensate on it and then freeze to the point where you should end up with a block of ice where the LNB was (that might be OK if the LNB's PCB is protected from moisture). If you can get it to minus 30C with a butchered domestic freezer, some of the things we came up with when looking at the practicalities of this were running costs, lagging, strengthening the LNB arms and using a thermostat. If you lag it and seal it at the same time, the actual moisture available to condensate could be almost completely removed. With good lagging, the actual energy needed could be greatly reduced and the efficiency could be increased and with a stat you could turn it up and down or off depending on the particular satellite (hmm like a super charger) but if it were off, with the lagging it might mean that it actually gets hotter than normal and may need a bit of cooling. | |||
| | |
| | #13 | |||
| Mod and septic resident Join Date: 01-01-2000 Location: London SW
Posts: 7393
Thanks: 1
Thanked 43 Times in 41 Posts
| n. 1. A means of escape or release from confinement; an outlet: give vent to one's anger. 2. An opening permitting the escape of fumes, a liquid, a gas, or steam
__________________ There is a very fine line between "hobby" and "mental illness" | |||
| | |
| | #14 | |||
| Design Engineer/Installer Join Date: 08-08-2007 Location: Central UK near Jodrell
Posts: 382
Thanks: 24
Thanked 44 Times in 43 Posts
My System: 75e-75w C & KU, 36v diseqc Anlg to HD Channel Master C120 dishes, stbs, lnbs, motors, too much to list | Ice build's up in freezers or Fridge ice boxes... .. leave the door open (& increase the ventilation(1&2)) and it will increase to the point where you'll just end up with a plug of ice, close the door and you can only freeze the moisture in the air in the fridge/ freezer- if there were no water vapour - no ice would form. 99% of ice that builds up in a freezer or ice box is from your kitchen /house. Every time you open the door of a freezer/ fridge, the cold, dry air drops out and onto the floor of your kitchen and draws the kitchen's warm, moist air in at the top. The moisture then condensates on the elements ....and quickly freezes (and still would with the door open & central heating on). In the case of sub zero temps, ventilation works the opposite way and outside there is rain etc. to deal with. There are plenty of low temp chemical processes that suffer from pipes being covered in ice. Whether ice build up would effect the LNB is another issue.. it might not adversly effect it anyway once it's sealed as you suggested and then sealed in lagging. Un-compacted ice is a good insulator anyway. A meal time thought... ![]() .....all the ice in a freezer surrounding your food is made up of ... exhaled breath, evaporated sweat, evaporated bleach and cleaners, x amount of evaporation from your toilet, bath, shower, the dog's little accident, cigarette smoke, any drugs smoke, 1000s of chemicals given off by various products around the house, VOCs from redecorating, all laid down in layers ... it's actually quite full of ####. ![]() | |||
| | |
| | #15 | |||
| Mod and septic resident Join Date: 01-01-2000 Location: London SW
Posts: 7393
Thanks: 1
Thanked 43 Times in 41 Posts
|
Do a search on ice dam prevention, and you will see that with correct venting of any cold location will prolong a dry environment regardless of size, or temperature extreme.
__________________ There is a very fine line between "hobby" and "mental illness" | |||
| | |
| | #16 | |||
| Design Engineer/Installer Join Date: 08-08-2007 Location: Central UK near Jodrell
Posts: 382
Thanks: 24
Thanked 44 Times in 43 Posts
My System: 75e-75w C & KU, 36v diseqc Anlg to HD Channel Master C120 dishes, stbs, lnbs, motors, too much to list |
That is not the same as an isolated cooling element at minus 30c from a butchered freezer or peltier that air born moisture condensates and freezes on -30c (and you want it to be -30c). If you leave a freezer door open it will just carry on freezing until it goes beyond the door, as I said- even if the central heating is on. If you fire up a peltier on its own but with an appropriate cooler on the hot side- ice will form on the cold side. You routinely see gas bottles with ice build up in the middle of summer. This is very basic and not really worthy of too much other than if it causes too much of a problem then it needs dealing with. It's getting it to work and at low cost/ running cost that should be the focus. Also, if you vent it, you lose a lot of the efficiency - you need to do the opposite and lag it keeping the cold in. | |||
| | |
| | #17 | ||||
| Mod and septic resident Join Date: 01-01-2000 Location: London SW
Posts: 7393
Thanks: 1
Thanked 43 Times in 41 Posts
| I do prefer to keep the box of tricks completely isolated from the atmosphere, but hermetically sealing the feed/LNB from water vapour is virtually impossible once cooling elements have been fitted, as other technologies have discovered (optics in astronomy for example) . Adding non replaceable drying compounds into the mix is a no go area owing to their drop off in performance after a couple of weeks, which is why the commercial users in this industry use forced air switching dehydrator systems, often beyond standard atmospheric pressure, to keep the dewpoint and resultant moisture from affecting components, lowering the efficiency of the feed system and/or damage through corrosion. http://www.physicsforums.com/archive.../t-102760.html There is no need to dismiss a forced air operation in a subzero cooling system, except for the initial costs and constant energy requirement, as it is proven technology. http://www.etitelecom.com/17980.htm
__________________ There is a very fine line between "hobby" and "mental illness" | ||||
| | |
| | #18 | ||
| Regular Member Join Date: 26-07-2005 Location: London
Posts: 126
Thanks: 274
Thanked 7 Times in 7 Posts
My System: dvb-s pci card 85 cm offset dish | Hello, At -273 degrees Celcius inside an LNB; would a 1 metre dish act like a 5 metre and 10m like a 50 m??? If not that much , then how much better? You guys know your physics and how to calculate G/T and C/N and dB's... Thank you in advance. | ||
| | |
| | #19 | ||
| Mod and septic resident Join Date: 01-01-2000 Location: London SW
Posts: 7393
Thanks: 1
Thanked 43 Times in 41 Posts
|
__________________ There is a very fine line between "hobby" and "mental illness" | ||
| | |
| The Following User Says Thank You to Channel Hopper For This Useful Post: | divibi (22-08-2008) |
| | #20 | |||
| Design Engineer/Installer Join Date: 08-08-2007 Location: Central UK near Jodrell
Posts: 382
Thanks: 24
Thanked 44 Times in 43 Posts
My System: 75e-75w C & KU, 36v diseqc Anlg to HD Channel Master C120 dishes, stbs, lnbs, motors, too much to list | BTW.. The thread post 2 http://www.physicsforums.com/showpost.php?p=846711&postcount=2 describes the ‘use’ of freezing onto an element to trap vapour in another dehydration process demonstrating what I have said about condensation/ freezing- that is it is that good at extracting moisture out of the air. The process that is the main thread demonstrates the same problems and the air flow to a dryer element. That is that ventilation (in open air) is not anything you would want to do (unlike ventilation in a house for example) but a drying system in an enclosed environment is as I said earlier, if there is no vapour in the air it will not result in ice build up (or condensation). It doesn’t say if they are using a cooler at the uplink or this is a passive system for general dry air/ minimal condensation. I have been involved in engineering/ chemical projects that, although not directly radio electronic cooling related, give you the experience of the kind of other problems that will arise trying to cool any object like that. The worst issue may be condensation and ice in the feed horn/ wave guide and on the antennae (and down the connected coax). Until you try it you don’t know, the gains may out way the problems or have to be dealt with. Lagging: Dr Dish & RD100‘s.… cooling with freezer spray.. A far better test and result is to use lagging… when you use freezer spray to freeze a water pipe, you lag the pipe- you can’t do it without lagging - the lagging increases the freezing massively and retains it. If Dr Dish had lagged the LNB and pushed the freezer spray through a small hole instead, the temperature would have been far lower. The same goes for a proper setup and lagging will reduce condensation and freezing air bourn vapour as well as make it far more efficient. Divibi The noise reduction gains we are after are in the order of the equivalent of 10-20-30% (40-50% would be fantastic but doubtful and certainly not those massive gains you have mentioned- we wish)… say a 1m acting like a 1.2- 1.3m or a 1.2 like a 1.5 to be realistic (in actual signal to unwanted noise wise- not signal strength- that shouldn’t alter with this). From our point of view in the UK there is a planning limit of 1 x 1m & 1 x 60cm dish per property now, so maximising a 1m rather than just getting bigger ugly dishes is attractive for a lot of people as well as bigger enthusiast’s ground based dishes gaining. Bigger dishes also have their problems too, weight, wind effect increases and needing 36v and far stronger gear all round etc.. this can help avoid some of this so it might be worth a bit of trouble. | |||
| | |
| The Following User Says Thank You to pedro2000uk For This Useful Post: | divibi (23-08-2008) |
| | #21 | ||||||||
| Mod and septic resident Join Date: 01-01-2000 Location: London SW
Posts: 7393
Thanks: 1
Thanked 43 Times in 41 Posts
|
Optics (binoculars/telescopes) use a nitrogen or other inert atmosphere, but again this requires hermetical sealing, almost impossible where a microwave transparent feedhorn is a neccessity. When carrying out tests, it was found that cooling of the air inside the feedhorn (and the feedhorn itself) also improved the C/N ratio, however the advantages were only 5%-10% that of freezing the LNB directly.
Did I mention that I sold dehydrators and Ice heaters for quite a few years in the commercial sector ?
__________________ There is a very fine line between "hobby" and "mental illness" | ||||||||
| | |
| | #22 | |||
| Design Engineer/Installer Join Date: 08-08-2007 Location: Central UK near Jodrell
Posts: 382
Thanks: 24
Thanked 44 Times in 43 Posts
My System: 75e-75w C & KU, 36v diseqc Anlg to HD Channel Master C120 dishes, stbs, lnbs, motors, too much to list |
| |||
| | |
| | #23 | ||||
| Mod and septic resident Join Date: 01-01-2000 Location: London SW
Posts: 7393
Thanks: 1
Thanked 43 Times in 41 Posts
|
No - the idea is to keep the heat components (the radiator or low pressure side of the fridge) away from the LNB, which is why the use of a refrigeration plant has so many advantages over the Peltier units. The heat transfer components are kept well away from the LNB, best place is strapped to the back of the reflector, but in front of the mount/motor, and then the pipes carrying the freon/halide can be of rigid construction.