Recent content by chuckiman

  1. C

    C/KU Band Linux Receivers

    The is also the ET8000 any info about that?
  2. C

    C/KU Band Linux Receivers

    Thanks Llew for the information. In this case the LNB got to be a C/KU band LNB?.
  3. C

    C/KU Band Linux Receivers

    )(-red:confused:I am having AD3000IP receiver and want a new box,is the Clarke Tech ET9000 having the C/KU band capability? if not which box with Linux system that is having this function.
  4. C

    Schematic For Echostar AD3000ip Power Supply

    Thanks very much Llew for the info, I will work on it this week end and post back my result.
  5. C

    Schematic For Echostar AD3000ip Power Supply

    Thanks very much Llew for your help i appreciate it. I have tried to use echoloader but did not work.I do not know which one of them is the Eeprom ?.There is one marked EAP7001 is it the eeprom?.I can fined a repaire shop to disolder it. I have the Willem Eeprom programmer but do not know if i...
  6. C

    Schematic For Echostar AD3000ip Power Supply

    Hi,Need help with my 3000ip,when i push the power on the display just keeps going round and round.I have check the power supply and i got the following reading:- SKEW = 4.8 - 5.3v M-P = 4.2-4.5v WEST = 4.8-5.3v EAST = 4.8-5.3v 5VS = 4.9-5.4v PCS = 4.3-4.9v 30V = 33.4-34v 21V =...
  7. C

    Schematic For Echostar AD3000ip Power Supply

    After setting the time and date. E.g 10:00 the time gets to 10:10 and back to 10:00 just like that keep on repeating and the date also stays the same without change
  8. C

    Schematic For Echostar AD3000ip Power Supply

    The clock is not working.Stays at 00:00 .
  9. C

    Schematic For Echostar AD3000ip Power Supply

    Hi Llew I have solve the problem with the standby. Q2 was the fault,it was not turning off Q5 which control the 30 volt outputs of the power supply.now i have two fans connected one for my DB. cam and the other for the power supply and the work fine. They go off when i put the box on standby.I...
  10. C

    Schematic For Echostar AD3000ip Power Supply

    Thanks Llew for the reply. am also shock that the box keeps on working i can say fine if not for the heating. Its almost 10PM here now so am going to try to work on it tomorrow.I will check am sue i have some electrolytic capacitors an change the and see what it give.
  11. C

    Schematic For Echostar AD3000ip Power Supply

    Hi Llew I have open my box and made some measurements on the voltages.I will like to ask ,used multimeter and measured AC and DC voltages on the transistors.should i have AC voltages on DC circuits ?.On the secondary side i have been able to measure AC voltages on every point.At the 30v i have...
  12. C

    Schematic For Echostar AD3000ip Power Supply

    Thanks Llew for this info. I will check this on friday evening and will give you a feedback.
  13. C

    Schematic For Echostar AD3000ip Power Supply

    Thanks Llew waiting to hear from you.
  14. C

    Schematic For Echostar AD3000ip Power Supply

    Thanks Llew waiting to hear from you.
  15. C

    Schematic For Echostar AD3000ip Power Supply

    Thanks for the fast response Llew.That's what i mean,Standby.is there another way to connect it so that it turn off on standby mode ?.Thanks for your help.
Top